Parameters | |
---|---|
Input voltage | 110/230 VAC / 50/60 Hz |
Input voltage tolerance | 15 % |
Effective cutting range | 1525 x 3050 mm |
Cutting process | plasma and oxy-fuel |
Plasma cut - recommended mild steel thickness | up to 35 mm |
Oxy-fuel cut - recommended mild steel thickness | up to 100 mm |
Flash back protection | yes |
Oxy-fuel torch included | yes |
Plasma torch included | no |
Plasma torch holder size | 35 mm |
Offline nesting software included | yes |
THC control for plasma cutting by arc voltage | yes |
Oxy-fuel THC control | manual |
Type of gases | Propane |
LCD screen | 7“ |
Library of common shapes | 50 |
Internal memory | 4 GB |
USB port for the drawings loading | yes |
Torch lifter stroke | 100 mm |
Number of solenoid valves | 3 |
Plasma torch collision protection | yes |
Weight net/gross | 134 kg / 207 kg |
Type of plasma ignition | contact |
Parameters | |
---|---|
Cutting range | 3–300 mm |
Fuel gases | oxygen-acetylene, oxygen-propane, natural gas, mixed gases |
Maximum cutting speed | 750 mm/min. (10 mm) |
Average cutting speed | 520 mm/min. (30 mm) |
Minimum cutting speed | 120 mm/min. (300 mm) |
Max. cutting oxygen pressure | 8.5 bar |
Min. preheating oxygen pressure | 1.6 bar |
Max. acetylene pressure | 1.2 bar |
Min. acetylene pressure | 0.5 bar |
Max. propane pressure | 1.0 bar |
Min. propane pressure | 0.2 bar |
Assembely | |
fittings flashback arrestors shut-off valves torch consumables fixing nut |
|
Dimensions | |
Gases inputs |
cutting OXY: G1/4" preheating OXY: G3/8" fuel gas: G3/8" LH |
Diameter of the torch body | 32mm. |
Lenght | 250 mm |
Optical system | |
---|---|
Focal lenght (magnification) |
125 mm (1.25) 150 mm (1.50) 175 mm (1.75) 200 mm (2.00) |
Adjustment range focusing (horizontal) | ±1 mm |
Wavelenght | 1030 up to 1130 nm |
Max. laser power | 8 kW |
Max. beam parameter acceptance (half angle) | 125 mrad |
Laser light cable receiver | Optoskand QBH, Trumpf-D |
Diameter laser light cable | up to 200 μm |
Focus range | |
Magnification | 1.25 1.50 1.75 2.0 |
In work piece direction (-) | 9 mm 13 mm 18 mm 20 mm |
In nozzle direction (+) | 6 mm 9 mm 13 mm 15 mm |
Correction range / offset Z-axix +/- | 1 mm 1.5 mm 2 mm 3 mm |
Housing | |
Dimensions | 118 × 116 × max 388 mm (depending on configuration) |
In work piece direction (-) | 9 mm 13 mm 18 mm 20 mm |
In nozzle direction (+) | 6 mm 9 mm 13 mm 15 mm |
Correction range / offset Z-axix +/- | 1 mm 1.5 mm 2 mm 3 mm |
Supply | |
Electric | DC 24 V / max. 4 A |
Process gas | inert and active gases, max. 25 bar |
Cooling gas | Air, max. 5 bar Flow min. 1.5 l/min |
Cooling circuit | Operating pressure max. 5 bar |
Specifications | |
---|---|
Cutting current | 10-30 A |
Input voltage | 220-240 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE, C-TICK, CCC |
Modes | cutting |
Frequency | 50/60 Hz |
Maximum input power | 4.9 kVA |
Output voltage | 92 VDC |
Duty cycle @ 40°C | 35 % @ 30 A; 100 % @ 21 A |
Dimension (L×H×W) | 480×290×165 mm |
Weight | 10.5 kg |
Recommended cutting capacity | 8 mm∗ |
Severance cutting capacity | 10 mm +∗ |
Piercing cutting capacity | 8 mm∗ |
Air flow [lpm/bar] | 48/4.5 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | H/F |
Type of hand torch | FHT-EX∗30H |
Specifications | |
---|---|
Recommended cutting capacity | 8 mm∗ |
Maximum capacity | 10 mm +∗ |
Piercing capacity | 8 mm∗ |
Plasma cutting | -10° C to +40° C |
Transport and storage | -25° C to +55° C |
Relative humidity | up to 90 % at 20° C |
Application process | plasma cutting |
Type of use | manual |
Pilot current | 10-18 A |
Rated current and corresponding duty cycle | 30 A / 100 % |
Type of gas | compressed air |
Gas flow rate | approx. 48 l/min |
Operating pressure | dynamic 4.5 bar / static 6.0 bar |
Min./max. operating pressure | 3.5-5.0 bar |
Type of voltage | DC direct voltage |
Protection type of the power supply-side connections | IP3X (EN 60 529) |
Type of connection | fixed |
Voltage rating | 500 V peak value |
Rated value of control leads (trigger and cap sensor) | 42 VAC / 0.1-1.0 A |
Standard lenght | 4 m |
Structure of cable | (Bikox) compact cable |
Weight | 4 m / 1.2 kg |
Specifications | |
---|---|
Cutting current | 10-30 A (120 VAC) / 10-40 A (230 VAC) |
Input voltage | 100/240 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE, C-TICK, CCC |
Modes | cutting / grid cutting |
Frequency | 50/60 Hz |
Maximum input power | 3.45 kVA @ 120 VAC / 5.98 kVA @ 230 VAC |
Output voltage | 140 VDC |
Duty cycle @ 40° C @ 230 VAC | 40 % @ 40 A, 100 % @ 25 A |
Dimension (L×H×W) | 469×228×177 mm |
Weight | 11.8 kg |
Recommended cutting capacity | 12 mm∗ |
Severance cutting capacity | 20 mm +∗ |
Min./max. operating pressure | 3.5-5.0 bar |
Piercing cutting capacity | 8 mm∗ |
Air flow [lpm/bar] | 120/4.5 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | H/F |
CNC interface | yes |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®40H |
Type of standard machine torch | FHT-EX®40M |
Specifications | |
---|---|
Recommended cutting capacity | 12 mm∗ |
Maximum capacity | 20 mm +∗ |
Piercing capacity | 8 mm∗ |
Plasma cutting | -10° C to +40° C |
Transport and storage | -25° C to +55° C |
Relative humidity | up to 90 % at 20° C |
Application process | plasma cutting |
Type of use | manual and mechanized |
Pilot current | 10-18 A |
Rated current and corresponding duty cycle | 40 A / 100 % |
Type of gas | compressed air |
Gas flow rate | approx. 120 l/min |
Operating pressure | dynamic 4.5 bar/static 6.0 bar |
Min./max. operating pressure | 3.5-5.0 bar |
Type of voltage | DC direct voltage |
Protection type of the power supply-side connections | IP3X (EN 60 529) |
Type of connection | TCS (torch conn.system) - 13 pin |
Voltage rating | 500 V peak value |
Rated value of control leads (trigger and cap sensor) | 42 VAC / 0.1-1 A |
Standard lenght | 4 m / 5 m / 7.5 m / 15 m |
Structure of cable | (Bikox) compact cable |
Weight | 4 m / 1.2 kg 7.5 m / 1.8 kg 5 m / 1.4 kg 15 m / 3.2 kg |
Specifications | |
---|---|
Cutting current | 20-25 A @ 120 VAC / 20-45 A @ 230 VAC |
Input voltage | 120-230 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE / C-TICK / CCC |
Modes | cutting / grid cutting / gouging |
Frequency | 50/60 Hz |
Maximum input power | 4.4 kVA @ 120 VAC / 7.59 kVA @ 230 VAC |
Output voltage | 145 VDC |
Duty cycle @ 40° C @ 120 VAC | 40 % @ 25 A, 100 % @ 16 A |
Duty cycle @ 40° C @ 230 VAC | 50 % @ 45 A, 100 % @ 32 A |
Dimension (L×H×W) | 469×228×177 mm |
Weight | 12.7 kg |
Recommended cutting capacity | 12 mm∗ |
Severance cutting capacity | 25 mm +∗ |
Piercing cutting capacity | 10 mm∗ |
Air flow [lpm/bar] | 90/4.5 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | F |
CNC interface | yes |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®45TTH |
Type of machine torch | FHT-EX®45TTM |
Specifications | |
---|---|
Cutting current | 20-45 A |
Input voltage | 3x400 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE / C-TICK / CCC |
Modes | cutting / grid cutting / gouging |
Frequency | 50/60 Hz |
Maximum input power | 6.48 kVA |
Duty cycle @ 40° C | 80 % @ 45 A, 100 % @ 40 A |
Dimension (L×H×W) | 469x228x177 mm |
Weight | 12.7 kg |
Recommended cutting capacity | 12 mm∗ |
Severance cutting capacity | 25 mm +∗ |
Piercing cutting capacity | 10 mm∗ |
Air flow [lpm/bar] | 90/4.5 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | F |
CNC interface | yes |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®45TTH |
Type of machine torch | FHT-EX®45TTM |
Specifications | |
---|---|
Recommended capacity | 12 mm∗ |
Maximum capacity | 25 mm +∗ |
Piercing capacity | 10 mm∗ |
Plasma cutting | -10° C to +40° C |
Transport and storage | -25° C to +55° C |
Relative humidity | up to 90 % @ 20° C |
Application process | plasma cutting, gouging |
Type of use | manual and mechanized |
Pilot current | 20 A @ 45 A setting |
Rated current and corresponding duty cycle | 45 A / 100 % |
Type of gas | compressed air / nitrogen |
Gas flow rate | approx. 90 l/min |
Max. inlet pressure | 10 bar |
Operating (dynamic) pressure | 4.8 bar |
Type of voltage | DC direct voltage |
Protection type of the power supply-side connections | IP3X (EN 60 529) |
Type of connection | TCS (torch conn.system) - 13 pin |
Voltage rating | 500 V peak value |
Rated value of control leads (trigger and cap) sensor) | 42 VAC / 0.1-1.0 A |
Standard lenght | 5 m / 8 m / 15 m |
Structure of cable | (Bikox) compact cable |
Weight | 5 m / 1.5 kg 8 m / 2.2 kg 15 m / 3.6 kg |
Specifications | |
---|---|
Cutting current | 30-55 A |
Input voltage | 3×220 VAC ± 15 % / 3×400 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE, C-TICK, CCC |
Modes | cutting / grid cutting / gouging |
Frequency | 50/60 Hz |
Maximum input power | 11.9 kVA @ 3×220 VAC / 13.7 kVA @ 3×400 VAC |
Output voltage | 140 V @ 3×220 VAC / 170 V @ 3×400 VAC |
Duty cycle @ 40° C @ 3×400 VAC | 50 % @ 55 A, 100 % @ 41 A |
Dimension (L×H×W) | 469×228×177 mm |
Weight | 11.8 kg |
Recommended cutting capacity | 20 mm∗ |
Severance cutting capacity | 30 mm +∗ |
Piercing cutting capacity | 20 mm∗ |
Air flow [lpm/bar] | 100/5.2 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | H/F |
CNC interface | optional |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®105RTXH |
Type of machine torch | FHT-EX®105RTXM |
Specifications | |
---|---|
Cutting current | 30-75 A |
Input voltage | 3×220 VAC ± 15 % / 3×400 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE, C-TICK, CCC |
Modes | cutting / grid cutting / gouging |
Frequency | 50/60 Hz |
Maximum input power | 14.71 kVA @ 3x220 VAC / 17.6 kVA @ 3x400 VAC |
Output voltage | 170 V (extra-boost 220 V) |
Duty cycle @ 40° C | 100 % @ 75 A |
Dimension (L×H×W) | 560x400x265 mm |
Weight | 24 kg |
Recommended cutting capacity | 25 mm∗ |
Severance cutting capacity | 35 mm +∗ |
Piercing cutting capacity | 25 mm∗ |
Air flow [lpm/bar] | 110/5.2 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | H/F |
CNC interface | optional |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®105RTXH |
Type of machine torch | FHT-EX®105RTXM |
Specifications | |
---|---|
Cutting current | 30-100 A |
Input voltage | 3x400 VAC ± 15 % |
Plasma gas | compressed air |
Certification depending on region | CE, C-TICK, CCC |
Modes | cutting / grid cutting / gouging |
Frequency | 50/60 Hz |
Maximum input power | 24.6 kVA |
Output voltage | 170 V (extra-boost 220 V) |
Duty cycle @ 40° C | 50 % @ 100 A, 100 % @ 80 A |
Dimension (L×H×W) | 560x400x265 mm |
Weight | 24 kg |
Recommended cutting capacity | 35 mm∗ |
Severance cutting capacity | 50 mm +∗ |
Piercing cutting capacity | 25 mm∗ |
Air flow [lpm/bar] | 135/5.2 |
Maximum input pressure [bar/psi] | 10/145 |
Protection level | IP23S |
Insulation class | H/F |
CNC interface | optional |
Preadjusted voltage divider ratio | 50:1 |
Type of hand torch | FHT-EX®105RTXH |
Type of machine torch | FHT-EX®105RTXM |
Specifications | 1st side |
---|---|
Rated current and corresponding duty cycle | 105 A / 100 % |
Recommended capacity | 35 mm∗ |
Maximum capacity | 50 mm +∗ |
Piercing capacity | 25 mm∗ |
Plasma cutting | -10° C to +40° C |
Transport and storage | - 25° C to +55° C |
Relative humidity | up to 90 % at 20° C |
Application process | plasma cutting, gouging, marking |
Type of use | manual and mechanized |
Gas flow rate | 105 A / 100 A approx. 135 l/min 85 A / 75 A approx. 110 l/min 65 A / 55 A approx. 98 l/min 45 A approx. 87 l/min |
Gas flow rate | gouging approx. 230 l/min |
Max. inlet pressure | 10 bar |
Operating (dynamic) pressure | 5.2 bar |
Type of voltage | DC direct voltage |
Protection type of the machine-side connections | IP3X (EN 60 529) |
Type of connection | TCS (torch connection system) - 13 pin |
Standard lenght | 8 m / 15 m |
Structure of cable | (Bikox) compact cable |
Specifications | 2nd side | |
---|---|---|
Type of gas | Air Recommended air quality ISO 8573-1 Class 1.2.2 Air max. particle size: 0.1 microns, class 1 ref. to ISO 8573 |
Nitrogen |
Gas quality specification | Air max. oil: 0.1 mg / m3, class 2 ref.: ISO 8573 Air max. dewpoint: +3° C, class 4 ref. to ISO 8573 |
Purity≥ 99.99 % |
Gas quality | clean, moisture-free, without oil | |
Weight FHT-EX®105RTXH Hand torch |
8 m / 3.3 kg 15 m / 5.6 kg |
|
Weight FHT-EX®105RTXM Machine torch |
8 m / 3.4 kg 15 m / 5.9 kg |